| SPECIFICATIONS |
|
|
| AC WITHSTAND VOLTAGE |
| |
Range
|
Resolution
|
Accuracy
|
| Output Voltage, ACV |
0-5000
|
1
|
± (2% of setting + 5V)
|
| Output Frequency |
50Hz/60Hz ±100ppm, User Selection |
| Output Waveform |
Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 |
| Output Regulation |
± (1% of output + 5V), From no load to full load |
| SETTINGS |
| HI and LO-Limit (Total), current, mA |
0.000-9.999 (0=OFF)
|
0.001
|
± (2% of setting + 2 counts)
|
|
10.00-40.00
|
0.01
|
| HI and LO-Limit (Real), current, mA |
0.000-9.999
|
0.001
|
± (3% of setting + 50µA)
|
|
10.00-40.00
|
0.01
|
| Ramp-Up Timer, second |
0.1 - 999.9
|
0.1
|
± (0.1% + 0.05 sec)
|
| Ramp-Down Timer, second |
0.0-999.9
|
| Dwell Timer, second |
0, 0.4 - 999.9
(0=continuous)
|
| Ground Continuity |
Current: DC 0.1 A ± 0.01A, fixed
|
|
Max. Ground Resistance: 1 Ω ± 0.1Ω, fixed
|
| Arc Detection |
1 - 9 ranges (9 is the most sensitivity)
|
| DC WITHSTAND VOLTAGE |
| Output Voltage, DCV |
0 -5000
|
1
|
± (2% of setting + 5V)
|
| DC Output Ripple |
<4 %(5KV/20mA at Resistive Load)
|
| SETTINGS |
| HI and LO-Limit, current, µA |
0.0 - 999.9
|
0.1
|
± (2% of setting + 2 counts)
|
|
1000 - 20000
|
1
|
| Ramp-Up Timer, second |
0.4 - 999.9
|
0.1
|
± (0.1% + 0.05 sec)
|
| Ramp-Down Timer, second |
0.0, 1.0-999.9
|
| Dwell Timer, second |
0, 0.3 - 999.9
(0=continuous)
|
| Ramp-HI, current |
>20 mA peak maximum, ON/OFF User Selection
|
| Charge-LO, current |
0.0 - 350.0 µA DC or Auto Set
|
| Discharge Time |
< 200 msec
|
Maximum Capacitive Load
DC Mode |
1µF < 1KV 0.08µF < 4KV
|
|
0.75µF < 2KV 0.04µF < 5KV
|
|
0.5µF < 3KV
|
| Ground Continuity |
Current: DC 0.1 A ± 0.01A, fixed
|
|
Max. Ground Resistance: 1 Ω ± 0.1Ω, fixed
|
| Arc Detection |
1 - 9 ranges (9 is the most sensitivity)
|
| INSULATION RESISTANCE |
| Output Voltage, DCV |
50 - 1000
|
1
|
± (2% of setting + 2 counts)
|
| Charging Current |
Maximum >20mApeak
|
| SETTINGS |
| HI and LO-Limit, resistance, MΩ |
0.05 - 99.99
(HI – Limit: 0 = OFF)
|
0.01
|
Same as Resistance MEASUREMENT Accuracy
|
|
100.0-999.9
|
0.1
|
|
1000-50000
|
1
|
± (0.1% + 0.05 sec)
|
| Ramp-Up Timer, second |
0.1 – 999.9
|
0.1
|
| Ramp-Down Timer, second |
0=OFF, 1.0-999.9
|
| Delay Timer, second |
0, 1.0 - 999.9
(0=continuous)
|
| Charge-LO, current, µA |
0.000 - 3.500 or Auto Set
|
| GROUND BOND |
| Output AC Current, A(7742 ) |
1.00 – 40.00
|
0.01
|
± (2 % of setting + 2 counts)
|
| Output Voltage, Vac |
3.00 – 8.00
|
0.01
|
± (2 % of setting + 3 counts)
|
| Output Frequency, Hz |
50Hz/60Hz ±100ppm, User Selection |
| Output Regulation |
± (1% of output + 0.02A), Within maximum load limits, and over input voltage range. |
| Maximum Loading |
1.00–10.00A/0–600mΩ, 10.01–30.00A/0–200mΩ, 30.01–40.00A/0–150mΩ |
| SETTINGS |
| Lead Resistance Offset, mΩ |
0-200
|
1
|
1.00-2.99A,± (3 % of setting + 3 counts )
3.00 - 30A,± (2 % of setting + 2 counts )
3.00 - 40A,± (2 % of setting + 2 counts )
|
| HI and LO-Limit Resistance, mΩ |
0 – 150 (30.01-40.00A)
|
1
|
|
0 – 200 (10.01-30.00A)
|
|
0 – 600 (1-10.00A)
|
| Dwell Timer, second |
0, 0.5 - 999.9
(0 = continuous)
|
0.1
|
± (0.1% + 0.05 sec)
|
| CONTINUITY TEST |
| Output Current, DC |
0.1A ± 0.01A, fixed |
| SETTINGS |
| Lead Resistance Offset, Ω |
0.00-2.00
|
0.01
|
± (3% of setting+2 counts)
|
| HI and LO-Limit, Resistance, Ω |
0.00 – 10.00 (0=OFF)
|
| Dwell Timer, second |
0,0.3-999.9
|
0.1
|
± (0.1% + 0.05 sec)
|
| Opt.734 (0 - 10kΩ) |
| Output Current |
DC 0.1A ± 0.01A,Max. |
| SETTINGS |
| Max-Lmt, Ω |
0.00 – 9.99
|
0.01
|
± (1% of setting+5 counts)
|
|
10.0 – 99.9
|
0.1
|
± (1% of setting+2 counts) |
|
100 – 999
|
1
|
|
1000 – 9999
|
1
|
| Min-Lmt, Ω |
0.00 – 9.99
|
0.01
|
± (1% of setting+5 counts)
|
|
10.0 – 99.9
|
0.1
|
± (1% of setting+2 counts) |
|
100 – 999
|
1
|
|
1000 – 9999
|
1
|
| Dwell Timer, second |
0.0, 0.3 – 999.9
(0 = continuous)
|
0.1
|
± (0.1% + 0.05 sec)
|
| Resistance Offset, Ω |
0.00 – 2.00
|
0.01
|
± (1 % of reading + 5 counts)
|
| MEASUREMENT |
| |
Range
|
Resolution
|
Accuracy
|
| Voltage, KV(AC/DC) |
0.00-5.00
|
0.01
|
± (1.5 % of reading +1 count)
|
| Voltage, Vdc (IR only) |
0-1000
|
1
|
± (1.5% of reading + 2 counts)
|
| AC Current (Total), mA |
0.000-3.500
|
0.001
|
± (2% of reading + 2 counts)
|
|
3.00-40.00
|
0.01
|
| AC Current (Real), mA |
0.000-9.999
|
0.001
|
± (3% of reading + 50?A)
|
|
10.00-40.00
|
0.01
|
All Ranges PF > 0.1 , V > 250VAC
|
| DC Current, µA |
0.0 - 350.0
|
0.1
|
± (2% of reading + 2 counts)
|
| DC Current, mA |
0.300 – 3.500
|
0.001
|
|
3.00-20.00
|
0.01
|
| AC Current, A (G.B for 7742 only) |
0.00-40.00
|
0.01
|
± (3 % of reading + 3 counts)
|
| Resistance, MΩ (IR) |
50-499V / 500-1000V
|
|
50 – 499V0.05–999.9, ±(7% of reading+2 counts)
|
|
0.050-1.999 / 0.050-9.999
|
0.001
|
500 – 1000V
|
|
2.00-19.99 / 0.050-9.999
|
0.01
|
0.10–999.9, ±(2% of reading+2 counts)
|
|
20.0-199.9 / 100.0-999.9
|
0.1
|
1000–9999, ±(5% of reading+2 counts)
|
|
200-50000 / 1000-50000
|
1
|
10000–50000, ±(15% of reading+2 counts)
|
| Resistance, mΩ (GB) |
0-600
|
1
|
1.00 – 2.99 A, ± (3 % of reading + 3 counts)
|
|
3.00 – 40.00 A, ± (2 % of reading + 2 counts)
|
| Resistance, Ω (Continuity) |
0.00-10.00
|
0.01
|
± (3 % of reading + 2 counts)
|
| Resistance, Ω (Continuity) Opt.734 |
0.00 – 9.99
|
0.01
|
± (1% of reading+5 counts)
|
|
10.0 – 99.9
|
0.1
|
± (1% of reading+2 counts) |
|
100 – 999
|
1
|
|
1000 – 9999
|
1
|
| GENERAL |
| Input Voltage AC |
115/230Vac±15%, 50/60Hz ± 5%, Fuse 10A/250V Slow-Blow for 7742 Model |
| PLC Remote Control |
Input : Test, Reset, Interlock, Recall File 1 through 10 |
| Output:- Pass, Fail, Test-in-Process |
| Memory |
50 memories, 30 steps/memory |
| Graphic Display |
320 x 240 Monographic LCD, 9 ranges contrast setting |
| Safety |
Built-in Smart GFI circuit,GFI trip current 450µA max, HV shut down speed: <1mS |
| Interface |
Standard RS232, Optional Printer Port with Date and Time Stamp or GPIB (IEEE-488.2). |
| Security |
Programmable password lockout capability to avoid unauthorized access to test set-up program. |
| Alarm Volume Setting |
Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. |
| Calibration |
Software and adjustments are made through the front panel. Automatic Calibration alert function to signal operator when re-calibration is due. |
| Environment |
0-40℃, 20-80%RH |
| Dimensions/Net Weight |
430mm(W)×133mm(H)×500 mm(D)/30Kg for MODEL 7742 |
| STANDARD ACCESSORIES |
| Power Cord(10A) |
×1
|
| Fuses |
×2 (Including a spare contained in the fuse holder)
|
| Interlock Disable Key(1505) |
×1
|
| Hipot Test Lead ,1.5m(1101) |
×1
|
Ground Bond Test Lead 40A
,1.6m(1137) |
×1
|
Ground Bond Return Lead 40A
,1.6m(1138) |
×1
|
| RS232 Link Cable 1.5m(1130) |
×1
|
| MATRIX SCANNER MODULE (Opt.736 for 7742) |
| High Voltage Rating |
5KVAC/5KVDC
|
| High Current Rating |
40 A
|
| Number of HV Channel |
8
|
| Number of HA Channel |
8
|
| RUN TEST MODULE (Opt.738,Opt.739 for 7742) |
| MEASUREMENT |
| |
Range
|
Resolution
|
Accuracy
|
| Voltage, Vac |
00.-277.0
|
0.1
|
± (1.5% of reading +2counts), 30.0-277.0V
|
| Current, Aac |
0.00-15.00
|
0.01
|
± (2.0% of reading + 2counts)
|
| Power, Watts |
0-4200
|
1
|
± (5% of reading + 3 counts)
|
| Power, Factor |
0.000-1.000
|
0.001
|
± (8% of reading + 2 counts)
|
| Leakage Current, mA |
0.00-10.00
|
0.01
|
± (2% of reading + 2 counts)
|
| MD Circuit |
Leakage Current measuring resistance = 2KΩ±1% |
| Timer, second |
0.0-999.9
|
0.1
|
± (0.1% of reading + 0.05 sec)
|
| SETTINGS |
| HI and LO Limit AC Voltage, V |
0.0-277.0
|
0.1
|
± (1.5% of setting + 0.2 V), 30.0-277V
|
| HI and LO Limit AC Current, A |
0.00-15.00
|
0.01
|
± (2.0% of setting + 2 counts)
|
| HI and LO Limit AC Power, W |
0 - 4200
|
1
|
± (5.0% of setting + 3 counts)
|
| HI and LO Limit Power Factor |
0.000-1.000
|
0.001
|
± (8% of setting + 2 counts)
|
| HI and LO Limit Leakage Current |
0.00-10.00, Hi-Limit 0=OFF
|
0.01
|
± (2% of setting + 2 counts)
|
| Delay Time, second |
0.2-999.9
|
0.1
|
± (0.1% + 0.05 sec)
|
| Dwell Time, second |
0, 0.1-999.9 (0=continuous)
|
| Cold Resistance |
0~10KΩ |
| DUT POWER |
| AC Voltage |
0 - 277.0V, Single phase unblance, 0 - 15.0A maximum |
| Power Rating |
4200 W maximum |
| DUT Protection |
Short circuit current 23A, <3 sec, Inrush Current 68A Response time 1m sec |
| STANDARD ACCESSORIES |
| Power Cord(15A) |
×1
|
| LLT Receptacle Adaptor Box 20A ,1.6m(1905) |
×1
|
| LINE LEAKAGE TEST MODULE (Opt.739 for 7742) |
| CURRENT MEASUREMENT |
| Frequency Range |
DC-1MHz
|
| Leakage Current Range (RMS) |
Resolution |
Accuracy (DC-100KHz) |
Accuracy ( >100KHz to 1 MHz) |
| 0.0µA - 999.9µA |
0.1µA
|
±(1.5% of reading + 3counts)
|
±(5% of reading + 5µA)
|
| 1000µA - 6000µA |
1µA
|
±(1.5% of reading + 3counts)
|
| Leakage Current Range (Peak), Opt.739 Only |
Resolution |
Accuracy (DC-100KHz) |
Accuracy ( >100KHz to 1 MHz) |
| 0.0µA - 999.9µA |
0.1µA
|
±(10% of reading + 2µA)
|
±(10% of reading + 2µA)
|
| 1000µA - 6000µA |
1µA
|
| LINE VOLTAGE MEASUREMENT |
| Range |
0.0-277.0 VAC |
| Resolution |
0.1 V |
| Accuracy |
± (1.5% of reading +0.2V), 30.0-277.0V |
| DUT |
| DUT Input Power Rating |
0-277V,AC@ 15Aac max |
| DUT Protection |
Short circuit current 23A, <3 sec, Inrush Current 68A Response time 1m sec |
| SETTINGS |
| High/Low Limit, µA |
Range 0.0 - 6000µA(0=OFF) , Resolution 0.1µA |
| Delay Time, second |
Range 0, 1.0-999.9 (0=continuous), Resolution 0.1second |
| Compliance Standards |
A UL544 Non Patient, UL484, IEC60598, UL1363 |
| B UL544 Patient Care |
| C UL2601-1, IEC60601-1, EN60601-1 |
| D UL1563 |
| E UL60950, IEC60950, IEC61010-1, IEC60335-1, IEC60990 Fig4 U2 |
| F IEC60990 Fig5 U3 |
| G IEC60990 Fig3 U1 |
| MD A - G components |
Accuracy: Resistance ± 1% Capacitor ± 5% |
| MD Voltage Limit |
Maximum 30V peak or 30VDC |
| STANDARD ACCESSORIES |
| Hipot Return Lead ,1.8m(1102) |
×2 |
| *product specifications are subject to change without notice. |